Skip to content
Omnikalc

Timber lagging thickness calculator: lumber size for an excavation support wall

Enter the earth pressure on the lagging, the span between the soldier piles, the support condition and the allowable bending stress to get the moment, the required section modulus and thickness, and the next standard lumber size.

Updated on
Your inputs
psf

Value out of range

ft

Value out of range

psi

Value out of range

Results

Next standard lumber thickness

5.50 in

Nominal 6x lumber (5.5 in actual)
Bending moment per foot of wall
3,360 lb·ft/ft
Section modulus required per foot of wall
33.6 in³/ft
Thickness required
4.10 in

The timber lagging thickness calculator finds the bending moment, the section modulus and the thickness of the lumber for a soldier pile and lagging excavation wall, and rounds it to the next standard lumber size.

How the calculation works

  • Enter the design earth pressure on the lagging at the depth considered (from the apparent pressure diagram of the wall) and the clear span between the soldier piles.
  • Choose the support condition: a simple span, or a continuous board over three or more piles.
  • Enter the allowable bending stress of the lumber, which may be increased for a temporary structure.
  • The calculator finds the moment M = w L² / 8 (or / 10) for a one-foot strip, the section modulus and the thickness t = √(6 S / b), and gives the next standard lumber thickness.

Example

A soldier pile and lagging wall has a design pressure of 420 psf at the depth considered and piles at 8 ft clear spacing, with simple spans. The moment is 420 × 64 / 8 = 3,360 lb·ft per ft of wall. With an allowable stress of 1,200 psi, the section modulus required is 3,360 × 12 / 1,200 = 33.6 in³/ft, and the thickness required is √(6 × 33.6 / 12) = 4.10 in. The next standard size is 5.5 in, a nominal 6x lumber.

Why it matters

The calculator helps excavation contractors, geotechnical and civil engineers, safety officers and students to choose the lagging size for a temporary shoring wall, to check the lumber on site and to compare spacings of the soldier piles. It gives the answer for each depth of the wall.

Good to know

Compute the lagging for the greatest pressure at each depth, and use thicker boards at the bottom. Keep the boards tight against the soil, and wedge them securely, since voids behind the lagging let the soil move. Check the shear and the deflection. Have a competent person inspect the shoring each day.

The Rankine earth pressure calculator gives the pressure from the soil, the retaining wall calculator covers permanent walls, the wood beam span calculator covers lumber spans and the beam deflection calculator checks deflections.

Frequently asked questions

What is soldier pile and lagging?

A soldier pile and lagging wall supports the sides of an excavation. Steel H-piles or beams, the soldier piles, are driven or drilled at a regular spacing, typically 6 to 10 ft, and timber boards, the lagging, are placed between them as the excavation goes down. The lagging holds the soil between the piles and transfers the earth pressure to the piles, which carry it to the ground and the braces or anchors.

How is the pressure on the lagging chosen?

The lagging does not take the full triangular earth pressure. Because the soil arches between the piles, the design pressure is taken from the apparent pressure diagram used for braced excavations, or as a reduced value of the earth pressure at the depth of each board. Lagging is designed for the greatest pressure at each depth, so the boards at the bottom are thicker than those at the top.

Why a continuous or a simple span?

A board that rests on more than two piles is continuous, with a smaller bending moment of wL²/10 instead of wL²/8, but the real support condition on site is uncertain because boards are cut and wedged against the flanges. A simple span is the safe and usual assumption. A wall with boards that are not continuous, or that have gaps, should use a simple span.

What allowable stress should I use?

For a temporary structure, building codes and the NDS allow a load duration increase of 25% or more on the bending stress of lumber. Common grades such as Douglas fir No. 2 have an allowable bending stress of about 900 to 1,200 psi for the sizes used in lagging. Check the moisture condition, which reduces the stress in wet or saturated ground, and check the shear and the deflection of the boards too.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.