A gas that accelerates or slows without friction or heat exchange follows the isentropic relations. The isentropic flow calculator takes the Mach number, the gas and the static temperature and pressure and gives the stagnation temperature, the stagnation pressure, the pressure and density ratios, the area ratio to the throat, the flow speed and the flow regime.
How the calculation works
- Temperature ratio T₀ ÷ T = 1 + (γ − 1) ÷ 2 × M², where γ is the ratio of specific heats and M the Mach number.
- Pressure ratio p₀ ÷ p = (T₀ ÷ T)^(γ ÷ (γ − 1)) and density ratio ρ₀ ÷ ρ = (T₀ ÷ T)^(1 ÷ (γ − 1)).
- Area ratio A ÷ A* = (1 ÷ M) × [(2 ÷ (γ + 1)) × (1 + (γ − 1) ÷ 2 × M²)]^((γ + 1) ÷ (2 × (γ − 1))). It compares the cross-section with the throat where the flow would be sonic.
- Flow speed = M × √(γ × R × T), where R is the specific gas constant and T the static temperature in kelvins.
Example
Air flows at Mach 2 at a static temperature of 60 °F (288.7 K) and a static pressure of 14.7 psi. The temperature ratio is 1 + 0.2 × 4 = 1.8, so the stagnation temperature is 476 °F. The pressure ratio is 1.8^3.5 = 7.82, so the stagnation pressure is 115 psi. The area ratio is 1.688, and the flow speed is 2 × 340.6 m/s = 1 524 mph.
Why it matters
The relations are the basis of nozzle, diffuser, wind tunnel and engine inlet design. They let you find the total pressure that a probe reads, size a nozzle for a given exit Mach number, and check how much the gas compresses at a given speed.
Good to know
The model assumes a perfect gas with a constant ratio of specific heats, steady one-dimensional flow, and no shocks, friction or heat transfer. The constants given for steam and combustion gas are typical values, and real gases change with temperature. Use a real-gas table for high temperature or high pressure, and treat the flow speed as the speed in the gas.
Related tools
The Mach number calculator gives the Mach number from a speed and the temperature, and the pitot tube calculator finds the speed from the pressure that the tube reads.