Skip to content
Omnikalc

Noise figure calculator: what is the noise figure of two stages in cascade?

Enter the noise figure and gain of the first stage, the noise figure of the second stage, the bandwidth and the SNR needed to get the cascaded noise figure, the noise temperature and the sensitivity.

Updated on
Your inputs
dB

Value out of range

dB

Value out of range

dB

Value out of range

Value out of range

dB

Value out of range

Results

Cascaded noise figure

1.37 dB

Equivalent noise temperature
108 K
Improvement over the second stage alone
6.63 dB
Minimum detectable signal
-102.6 dBm

In any receiver, the first amplifier sets how well weak signals can be picked out of the noise. The noise figure calculator takes the noise figure and gain of a first stage, the noise figure of a second stage, the bandwidth and the signal-to-noise ratio needed and gives the cascaded noise figure by the Friis formula, the equivalent noise temperature, the improvement over the second stage alone and the minimum detectable signal.

How the calculation works

  • Noise factor F = 10^(NF ÷ 10) for each stage, where NF is the noise figure in decibels.
  • Friis formula for two stages: F = F1 + (F2 − 1) ÷ G1, where G1 is the linear gain of the first stage, 10^(gain in dB ÷ 10). The first stage dominates when its gain is high.
  • Cascaded noise figure = 10 × log10(F), and the equivalent noise temperature = 290 K × (F − 1).
  • Minimum detectable signal = −174 dBm/Hz + 10 × log10(bandwidth in Hz) + NF + the signal-to-noise ratio needed. The −174 dBm per hertz is the thermal noise of a matched input at 290 K.

Example

A low-noise amplifier with NF 1.2 dB and 20 dB of gain is followed by a receiver with NF 8 dB. In linear terms F1 = 1.318, F2 = 6.31 and G1 = 100, so F = 1.318 + 5.31 ÷ 100 = 1.371, a cascaded noise figure of 1.37 dB and a noise temperature of 108 K. That is 6.63 dB better than the receiver alone. With a 1 MHz bandwidth and a required SNR of 10 dB, the minimum detectable signal is −174 + 60 + 1.37 + 10 = −102.6 dBm.

Why it matters

Designers of radios, satellite receivers, antennas, radar and instruments use the Friis formula to decide where to place a low-noise amplifier and how much gain it needs. Amateur radio operators use it to judge whether a preamplifier at the antenna is worth its cost.

Good to know

The calculation covers two stages. For more stages add the further terms (F3 − 1) ÷ (G1 × G2). Losses in cables and filters act as stages with a noise figure equal to their loss. The formula assumes matched impedances and a source at 290 K, and it ignores the sky or antenna noise, which can dominate at low frequencies.

The SNR calculator relates signal and noise levels and the dBm converter switches between power in watts and dBm.

Frequently asked questions

What is the noise figure?

The noise figure measures how much a device degrades the signal-to-noise ratio. A perfect device has a noise figure of 0 dB, and a device with a noise figure of 3 dB doubles the noise power compared to an ideal one. It is the ratio, in decibels, of the input to the output signal-to-noise ratio at a reference temperature of 290 K.

Why does the first stage matter most?

The noise of later stages is divided by the gain of the stages before them. A high-gain, low-noise amplifier at the front makes the noise of the following stages almost irrelevant. This is why a low-noise amplifier is placed at the antenna, before a long cable or a noisy receiver.

How is noise figure related to noise temperature?

They express the same thing: T = 290 K × (F − 1). A noise figure of 3 dB corresponds to a noise temperature of 290 K, and 1 dB to 75 K. Noise temperature is more convenient at very low noise levels, as in satellite and radio astronomy receivers.

What do I do with the minimum detectable signal?

It is the weakest signal that the receiver can detect at the chosen signal-to-noise ratio. Compare it with the signal level at the antenna from a link budget to check the margin. A narrower bandwidth lowers the noise floor by 3 dB for each halving.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.