Skip to content
Omnikalc

Bolt bearing and tearout strength calculator

Enter the bolt size, the plate, the edge distance, the spacing and the load to get the bearing and tearout strength of the edge bolt, the inner bolts and the line of bolts.

Updated on
Your inputs
in

Value out of range

in

Value out of range

ksi

Value out of range

in

Value out of range

in

Value out of range

Value out of range

kips

Value out of range

Results

Design strength of the line of bolts

117.2 kips

Nominal hole diameter
0.8125 in
Clear distance at the edge bolt
0.844 in
Design strength of the edge bolt
18.51 kips
Design strength of an inner bolt
32.91 kips
Load to capacity ratio
0.68
The plate bearing and tearout strength carries the load

The bolt bearing and tearout calculator gives the design strength of the plate at an edge bolt, at an inner bolt and for a line of bolts, using the edge distance and spacing, and compares it with the load.

How the calculation works

  • Enter the bolt diameter, the plate thickness and the tensile strength of the plate.
  • Enter the edge distance, the bolt spacing, the number of bolts in the line and the factored load.
  • The calculator gives the bearing and tearout strength of the edge bolt, of an inner bolt, of the line of bolts and the load to capacity ratio.

Example

A 3/8 in plate with Fu = 65 ksi is bolted with 3/4 in bolts, 1.25 in from the edge and at 3 in spacing, with deformation considered (1.2). The hole is 0.75 + 1/16 = 0.8125 in, so the clear distance at the edge is 0.844 in. The edge bolt has a design strength of 18.51 kips, an inner bolt 32.91 kips (limited by 2.4 d t Fu). A line of 4 bolts carries 117.2 kips, and a load of 80 kips gives a ratio of 0.68.

Why it matters

The calculator helps steel detailers, engineers, fabricators and students to check that the plate around a bolt hole is strong enough, to see how much the edge distance and the spacing matter, and to choose the number of bolts in a line.

Good to know

Use the real thickness of the thinnest connected part and the specified minimum tensile strength of the steel, and use the factored load in the direction of the line of bolts. When the inner bolt value is limited by the 2.4 d t Fu term, more spacing does not help, and you need a thicker plate or more bolts. A short edge distance is the most common reason for the lowest value, so check it first. Remember that the bolts must also carry the shear, and that the plate must also carry block shear and tension, so use the lowest value of all the limit states for the joint.

The bolt shear capacity calculator gives the strength of the bolt itself, the block shear calculator checks the tear of a group of holes, the steel tension member calculator checks the plate and the prying action calculator checks a tee stub in tension.

Frequently asked questions

What are bearing and tearout?

Bearing and tearout is the strength of the plate around the hole, not of the bolt. The bolt pushes on the plate and either crushes the material in front of the hole or tears a strip out toward the edge or the next hole. Short edge distances and close spacing lower the strength, and the plate can fail before the bolt does.

What is the formula in AISC 360?

For standard holes, the nominal strength of one bolt is Rn = 1.2 Lc t Fu, not more than 2.4 d t Fu, when the deformation of the hole matters at service load. When it does not matter, the factors are 1.5 and 3.0. Lc is the clear distance from the edge of the hole to the edge of the next hole or of the material, and the resistance factor is 0.75.

Why is the hole bigger than the bolt?

A standard hole is 1/16 in larger than the bolt, so the clear distance Lc is measured from the edge of the actual hole. The edge distance to the bolt center is reduced by half of the hole, and the spacing by a full hole. Slotted and oversized holes have different rules, and they are not covered by this calculator.

What does the calculator leave out?

The calculator leaves out the bolt shear and tension, the block shear, the net section of the plate, the minimum edge distances and spacings of the code, the effect of a load that is not parallel to the edge, and long slots. Check each of these limit states, and use the lowest of them for the connection.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.