The prying action calculator gives the parameters β and α’, the required flange thickness and the ratio to the thickness provided of a bolted tee-stub or end plate connection in tension, by the procedure of the AISC Steel Construction Manual.
How the calculation works
- Enter the thickness of the flange, the required tension and the available tension strength of one bolt.
- Enter the distance b from the bolt line to the web face, the distance a to the edge of the flange, the tributary length per bolt and the bolt diameter.
- Enter the tensile strength of the flange. The calculator finds β and the prying factor α’, the required flange thickness by the AISC procedure and the ratio to the thickness provided.
Example
A tee-stub flange of 0.75 in has bolts of 3/4 in with a required tension of 27 kips and an available strength of 29.8 kips, with b = 1.75 in, a = 1.5 in, a pitch of 4 in and Fu = 65 ksi. Then b’ = 1.375 in, a’ = 1.875 in, ρ = 0.733, δ = 1 − 0.8125 / 4 = 0.797, β = (29.8 / 27 − 1) / 0.733 = 0.141 and α’ = 0.207. The required thickness is √(4.44 × 27 × 1.375 / (4 × 65 × (1 + 0.797 × 0.207))) = 0.738 in, a ratio of 0.98.
Why it matters
The calculator helps steel designers, detailers and students to size the thickness of hanger connections, tee-stub connections and end plates in a first design, and to see how the bolt position, the pitch and the steel strength change the flange thickness needed.
Good to know
Keep the bolt line as close as possible to the web, within the clearance for the wrench, and use a thicker flange if the ratio is close to 1. Check also the bolts for the tension with the prying force, the flange in shear and the weld to the web.
Related tools
The bolt shear capacity calculator checks the bolts in shear, the bolt joint stiffness calculator shows the effect of the stiffness on the load in the bolts, the steel tension member calculator checks a plate in tension and the Whitmore width calculator checks a gusset plate.