Skip to content
Omnikalc

Cool roof sol-air temperature and heat gain calculator

Enter the roof area, the U-value, the solar load, the temperatures and the two reflectances to get the sol-air temperatures, the heat flux and the heat gain avoided.

Updated on
Your inputs
ft²

Value out of range

Btu/h·ft²·°F

Value out of range

Btu/h·ft²

Value out of range

°F

Value out of range

°F

Value out of range

Btu/h·ft²·°F

Value out of range

Value out of range

Value out of range

°F

Value out of range

Results

Peak heat gain avoided

45,833 Btu/h

Sol-air temperature, existing roof
163.0 °F
Sol-air temperature, cool roof
117.2 °F
Peak heat flux, existing roof
4.40 Btu/h·ft²
Peak heat flux, cool roof
2.11 Btu/h·ft²
Peak cooling avoided
3.82 tons
Reduction of the roof heat gain
52.1 %

The cool roof calculator gives the sol-air temperature of an existing roof and of a reflective roof, the peak heat flux through each, the peak heat gain avoided in Btu per hour and in tons, and the percentage reduction, from the reflectances, the solar load and the U-value.

How the calculation works

  • Enter the roof area, the U-value, the peak solar irradiance, the outdoor and indoor temperatures and the surface film coefficient.
  • Enter the solar reflectance of the existing roof and of the cool roof, and the long-wave correction.
  • The calculator gives the sol-air temperatures, the heat flux through each roof and the peak heat gain avoided.

Example

A roof of 20,000 ft² with a U-value of 0.05 is exposed to 250 Btu/h·ft² at an outdoor temperature of 95 °F, with a film coefficient of 3.0. The existing roof has a reflectance of 0.10, so its sol-air temperature is 95 + 0.90 × 250 / 3.0 − 7 = 163.0 °F and its heat flux is 0.05 × (163.0 − 75) = 4.40 Btu/h·ft². A cool roof of reflectance 0.65 reaches 117.2 °F and 2.11 Btu/h·ft². The peak heat gain avoided is (4.40 − 2.11) × 20,000 = 45,833 Btu/h, that is 3.82 tons, a reduction of 52.1 %.

Why it matters

The calculator helps roofing contractors, energy auditors, architects and building owners to see what a white or reflective roof is worth at the peak, to size the cooling saved and to compare a cool roof with more insulation.

Good to know

Compare the saving with the cost of the product, the climate and the insulation, since a cool roof pays most on a poorly insulated roof in a hot, sunny climate with air conditioning in a long season. Use the aged reflectance, not the new one, and check that the thermal emittance is high, since a bright metal with a low emittance heats more than a white membrane with the same reflectance. Keep the surface clean, as dirt lowers the reflectance.

The window solar heat gain calculator gives the sun through glass, the wall U-value calculator gives the transmittance of a layered wall, the heat loss calculator gives the winter loss of a house and the sensible envelope cooling load calculator gives the cooling load of a building.

Frequently asked questions

What is the sol-air temperature?

The sol-air temperature is the outdoor air temperature that would give the same heat flow into the roof as the real air temperature together with the sun and the radiation to the sky. It is T = To + α I / ho − ε ΔR / ho, where α is the solar absorptance, I the irradiance, ho the film coefficient and the last term the long-wave exchange, about 7 °F for a horizontal surface. The heat flux is the U-value times the difference between the sol-air and the indoor temperatures.

How does the reflectance change the heat gain?

The absorptance is 1 minus the solar reflectance, so a roof with a reflectance of 0.10 absorbs 90 % of the sun, and one with 0.65 absorbs 35 %. The sol-air temperature falls in proportion, and for a dark, poorly insulated roof it can fall by 40 °F or more. With good insulation the saving in heat flow is smaller, because the U-value is smaller, and in a cold climate the reflective roof can raise the heating load in winter.

Which reflectance should I use?

Use the aged solar reflectance listed for the product, for example in the rating of a cool roof council, because the new value drops by 10 to 20 % in the first years with dirt and weathering. A white single-ply membrane has a new reflectance of 0.75 to 0.85, a light-colored metal or a coating 0.60 to 0.75, and a dark asphalt shingle or a black membrane 0.05 to 0.15.

What does the calculator leave out?

The calculator takes a steady peak condition and one-dimensional heat flow, and it does not model the thermal mass of the roof, the ventilation of an attic, the heat storage, the winter penalty or the yearly energy. It gives a peak figure for sizing and for comparing options. For the yearly savings use an hourly energy model with the weather of your site.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.