Skip to content
Omnikalc

Field vane shear undrained strength and sensitivity calculator

Enter the peak and remolded torques, the vane size and the correction factor to get the undrained shear strength, the corrected strength and the sensitivity of a clay.

Updated on
Your inputs
lb-ft

Value out of range

lb-ft

Value out of range

in

Value out of range

in

Value out of range

Value out of range

Results

Corrected undrained shear strength

759 psf

Medium clay
Peak undrained shear strength
843 psf
Remolded shear strength
169 psf
Sensitivity
5.0
Sensitive clay: it loses strength when disturbed

The field vane shear calculator gives the undrained shear strength of a clay from the torque of a vane test, the corrected strength with the Bjerrum factor, the remolded strength and the sensitivity.

How the calculation works

  • Enter the peak torque and the remolded torque read on the vane test.
  • Enter the diameter and the height of the vane and the correction factor for the plasticity of the clay.
  • The calculator gives the undrained shear strength, the corrected strength, the remolded strength and the sensitivity.

Example

A vane 2.56 in in diameter and 5.12 in high is turned in a clay. The peak torque is 30 lb-ft. The strength is Su = T / (π D² (H / 2 + D / 6)) = 843 psf. With a correction factor of 0.9, the design strength is 759 psf, a medium clay. The remolded torque of 6 lb-ft gives a remolded strength of 169 psf, so the sensitivity is 5.0.

Why it matters

The calculator helps geotechnical engineers, site investigation crews and students to convert vane torques into strengths on site, to compare soft clay layers, to estimate the bearing capacity or the stability of an embankment and to find sensitive clays.

Good to know

Push the vane well below the bottom of the borehole, to avoid the disturbed zone, and turn it at the standard rate of about 6° per minute. Record the torque of the rod friction and subtract it from the readings. Use the correction factor that matches the plasticity of the clay, and compare the results with the laboratory tests of undisturbed samples. Check the calibration of the torque head and the rod coupling at regular intervals, and note the depth, the date and the weather in the log, since a vane test cannot be repeated in the same spot.

The Atterberg limits calculator gives the plasticity of a soil, the consolidation settlement calculator gives the settlement of a clay layer, the bearing capacity calculator gives the capacity of a footing and the soil nail pullout calculator gives the resistance of a nail.

Frequently asked questions

What does the vane test measure?

A vane of four thin blades is pushed into soft clay at the bottom of a borehole or directly from the surface, and then turned slowly. The peak torque needed to shear the cylinder of soil around the vane gives the undrained shear strength of the clay. After several fast turns, the clay is remolded and the torque is measured again, which gives the remolded strength. The test is for soft to medium saturated clays.

What is the formula?

For a vane with a height H and a diameter D, with the shear stress uniform on the sides and on the two ends of the cylinder, the torque is T = π D² (H / 2 + D / 6) Su. For the common vane with H = 2 D, this becomes Su = 6 T / (7 π D³). The calculator uses the general form, so it also works for vanes of other proportions.

Why is there a correction factor?

The field vane gives a strength that is higher than the strength that governs the failure of embankments and foundations, because of the rate of the test, the anisotropy of the clay and the progressive failure. Bjerrum proposed a correction factor μ, which depends on the plasticity index of the clay, from about 1.1 for low plasticity to about 0.6 for a plasticity index above 100. Use the factor of your design standard.

What does the sensitivity tell me?

The sensitivity is the ratio of the undrained strength of the undisturbed clay to its remolded strength. Most clays have a sensitivity between 2 and 4, a sensitive clay between 4 and 8, and an extra-sensitive or quick clay has more than 8 and can flow like a liquid when disturbed. The calculator does not cover vane tests in sand, in fissured clay or in stiff soils, where the test is not valid.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.