Skip to content
Omnikalc

Gear pump calculator: flow, leakage, power and torque of a hydraulic gear pump

Enter the displacement, speed, efficiencies and pressure of a gear pump to get the theoretical and actual flow, the internal leakage, the hydraulic power, the shaft power and the torque needed.

Updated on
Your inputs
in³/rev

Value out of range

rpm

Value out of range

%

Value out of range

psi

Value out of range

%

Value out of range

Results

Actual flow

7.17 gpm

Theoretical flow
7.79 gpm
Slip (internal leakage) flow
0.62 gpm
Hydraulic power
6.27 hp
Shaft power required
7.38 hp
Shaft torque
25.8 lb·ft

The gear pump flow and power calculator gives the theoretical and actual flow, the internal leakage, the hydraulic power, the shaft power and the torque of a positive displacement gear pump from its displacement, speed, pressure and efficiencies.

How the calculation works

  • Enter the displacement per revolution of the pump and its speed.
  • Enter the volumetric efficiency, which accounts for the internal leakage (90 to 95% for a new gear pump), the working pressure and the overall efficiency.
  • The calculator finds the theoretical flow Q = displacement × speed and the actual flow after the leakage.
  • It gives the hydraulic power Q × p, the shaft power after the overall efficiency and the torque needed at the shaft.

Example

A gear pump has a displacement of 1.2 in³/rev and turns at 1,500 rpm. The theoretical flow is 1.2 × 1,500 / 231 = 7.79 gpm. At 92% volumetric efficiency, the actual flow is 7.17 gpm, with a slip of 0.62 gpm. At 1,500 psi, the hydraulic power is 7.17 × 1,500 / 1,714 = 6.27 hp. With an overall efficiency of 85%, the shaft power is 7.38 hp, and the torque is 7.38 × 5,252 / 1,500 = 25.8 lb·ft.

Why it matters

The calculator helps hydraulic designers, maintenance engineers, mobile equipment and farm machinery owners, and students to size a gear pump and its drive, to estimate the effect of wear on the flow and to select a motor. It is a basic calculation for any hydraulic power pack.

Good to know

Use the efficiencies given by the manufacturer at the working pressure and the oil temperature. Size the motor or engine for the peak pressure, not for the average. Add a pressure relief valve. Check the suction line to avoid cavitation, and replace the pump when the volumetric efficiency has dropped under 85%.

The hydraulic motor torque calculator covers the motor side, the pump power calculator covers centrifugal pumps, the horsepower and torque calculator converts the power and the hydraulic accumulator sizing calculator sizes the accumulator.

Frequently asked questions

How is the flow of a gear pump computed?

A gear pump is a positive displacement pump: each revolution moves a fixed volume of oil, its displacement. The theoretical flow is the displacement times the speed, and the actual flow is that value times the volumetric efficiency, which accounts for the oil that leaks back from the high-pressure side to the suction through the clearances. The flow is nearly independent of the pressure, except for the leakage.

What is the volumetric efficiency?

The volumetric efficiency is the ratio of the actual flow to the theoretical flow. It is 90 to 95% for a new gear pump with oil of the right viscosity at moderate pressure, and it drops as the pressure rises, as the oil gets hotter and thinner, or as the pump wears. A fall in the volumetric efficiency below about 85% is the usual sign that a pump needs to be rebuilt.

How are the power and the torque found?

The hydraulic power is the actual flow times the pressure (divided by 1,714 in US units with gpm and psi, or by 600 with L/min and bar for kW). The shaft power is that value divided by the overall efficiency, which includes the volumetric and mechanical efficiencies, from 80 to 90%. The torque follows from the shaft power and the speed, and it is what the motor must supply.

What about the speed limits?

A gear pump must turn fast enough to fill its chambers, usually above 500 rpm, and below a maximum speed, often 3,000 to 3,500 rpm, beyond which cavitation starts at the suction. The maximum pressure is also limited by the bearings and the housing. Cold oil with a high viscosity needs a lower speed at start-up, and a relief valve must always protect the pump.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.