Piping or boiling happens when the upward seepage gradient at an exit reaches the critical hydraulic gradient of the soil. The piping safety factor calculator computes the critical gradient, the exit gradient, the safety factor and the head difference that causes boiling.
How the calculation works
- Enter the head difference between the upstream and downstream water levels, and the length of the seepage path along the base of the structure or around the sheet pile, in feet.
- Enter the exit gradient factor: 1 for the average gradient, and 1.5 to 2.5 near a sheet pile or a cutoff, where the flow lines concentrate at the downstream face.
- Enter the specific gravity of the grains and the void ratio of the soil at the exit. The calculator computes the critical gradient ic = (Gs − 1) / (1 + e), the gradient at which the effective stress is zero.
- The safety factor against piping is ic divided by the exit gradient. A value of 1.5 or more is a common minimum for an excavation, and 3 or more for a dam.
Example
A cofferdam has a head difference of 10 ft and a seepage path of 40 ft, with an exit gradient factor of 1.5. The soil at the exit has Gs = 2.67 and e = 0.70. The critical gradient is 1.67 / 1.70 = 0.982. The exit gradient is 1.5 × 10 / 40 = 0.375. The safety factor against piping is 0.982 / 0.375 = 2.62. The soil has a buoyant unit weight of 61.30 pcf, the seepage force is 23.40 pcf, and boiling would need a head difference of 26.20 ft.
Why it matters
The calculator helps civil and geotechnical engineers, contractors who dig below the water table, and students to check the base of a cofferdam, a deep excavation, a sheet pile wall or a small dam against boiling, and to see what a longer cutoff or a lower head would change. It is a quick screening before a full seepage analysis.
Good to know
Use the void ratio of the loosest soil at the exit, since it governs. Raise the exit gradient factor near a cutoff wall, and use a flow net or a finite element model for the final design. Add a filter or a weighted blanket at the exit to raise the safety factor. Lower the water table by dewatering when the margin is small.
Related tools
Darcy’s law calculator gives the seepage flow, the soil permeability test calculator measures the permeability, the porosity and void ratio calculator gives e and the infinite slope stability calculator covers the effect of seepage on a slope.