Sediment basin calculator: surface area and storage of a construction site basin

Enter the inflow, the particle size, the specific gravity, the disturbed area and the length to width ratio to get the settling velocity, the surface area, the length and the storage volume of a sediment basin.

Updated on
Your inputs
cfs

Value out of range

mm

Value out of range

Value out of range

acres

Value out of range

Value out of range

Results

Required surface area of the basin

20,396 ft²

Settling velocity of the particle
4.24 ft/h
Basin length
202.0 ft
Minimum storage volume
36,000 ft³

The sediment basin calculator gives the settling velocity of a target particle with Stokes’ law, the surface area, the length and the minimum storage volume of a sediment basin for a construction site, from the inflow, the particle size and the disturbed area.

How the calculation works

  • Enter the design inflow of the basin and the drainage area that is disturbed by the work.
  • Enter the diameter and the specific gravity of the smallest particle that you want to capture, and the length to width ratio of the basin.
  • The calculator finds the settling velocity with Stokes’ law, the surface area of the basin as 1.2 times the inflow divided by the velocity, its length and the minimum storage volume.

Example

A construction site of 10 acres sends 20 cfs to a sediment basin. The target is a silt particle of 0.02 mm with a specific gravity of 2.65. The settling velocity is 32.2 × 1.65 × (0.02 / 304.8)² / (18 × 0.0000108) × 3600 = 4.24 ft/h. The surface area is 1.2 × 20 / (4.24 / 3600) = 20,396 ft². With a length to width ratio of 2, the basin is 202.0 ft long, and the storage volume is 3,600 × 10 = 36,000 ft³.

Why it matters

The calculator helps site engineers, contractors, erosion control inspectors and students to size a temporary sediment basin or to check a design from a plan. It shows that the surface area, not the depth, controls the capture of the fine particles, and how fast the area grows when a smaller particle is targeted.

Good to know

Use the peak inflow of the design storm of the permit, not the average. Keep a length to width ratio of 2 or more, put the inlet and the outlet far from each other, and clean the basin when the sediment reaches half of the storage. Add an emergency spillway and a stable outlet.

The Stokes’ law calculator gives the settling velocity of any particle, the detention time calculator checks the residence time, the rational method calculator gives the peak inflow and the SCS curve number calculator finds the runoff depth.

Frequently asked questions

How is a sediment basin sized?

A sediment basin is sized on the surface area, because a particle settles when its settling velocity is higher than the overflow rate, which is the inflow divided by the surface area. The calculator finds the settling velocity of the target particle with Stokes’ law and the area that gives an overflow rate equal to that velocity, then multiplies by a factor of 1.2 to account for turbulence and short circuiting. A volume of storage for the sediment is added, often 3,600 ft³ per acre of disturbed land.

What particle size should be used?

Most erosion and sediment control rules ask to capture the 0.02 mm silt, because coarse sand and gravel settle in any basin, while clay of less than 0.002 mm cannot be captured without a flocculant. The 0.02 mm silt gives a settling velocity of about 4 ft/h (1.3 m/h), which needs a large area. A smaller particle gives a much larger area, since the velocity varies with the square of the diameter.

Why is the shape of the basin important?

A long and narrow basin, with a length to width ratio of 2 or more, gives a flow closer to a plug flow and less short circuiting. The inlet and the outlet must be placed at the opposite ends, and baffles are often added. The calculator gives the length for the ratio entered. The depth is usually 3 to 6 ft (1 to 2 m) and the outlet takes the water from the surface with a skimmer.

What are the limits of this calculator?

Stokes’ law is valid for small spherical particles in still water. The calculator does not include the real shape of the particles, the temperature, the flocculation, the wind, the inflow peak of a design storm routed through the basin, or the emergency spillway. The local stormwater permit gives the design storm and the required volume, and the design must be checked by a qualified engineer.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.