Skip to content
Omnikalc

Steel beam web local yielding and crippling calculator

Enter the dimensions of the beam, the yield stress, the bearing length, the position and the factored load to get the web yielding and crippling strengths and the ratio.

Updated on
Your inputs
in

Value out of range

in

Value out of range

in

Value out of range

in

Value out of range

in

Value out of range

ksi

Value out of range

kips

Value out of range

Results

Governing design strength

113.1 kips

Web local yielding, design strength
129.6 kips
Web local crippling, design strength
113.1 kips
Ratio of the load to the strength
0.80
The web resists the load

The steel beam web local yielding and crippling calculator gives the design strengths of the web under a concentrated load or an end reaction for the two limit states of AISC 360 J10, the governing strength and the ratio of your load to it, from the dimensions of the beam and the length of bearing.

How the calculation works

  • Enter the depth, the web and flange thicknesses and the distance k of the beam, with the yield stress of the steel.
  • Enter the length of bearing of the load, choose its position and enter the factored load.
  • The calculator finds the web local yielding and web local crippling strengths, the governing strength and the ratio of the load to it.

Example

A beam of 16 in. depth with a web of 0.305 in., a flange of 0.505 in., k = 1.0 in. and steel of 50 ksi carries a concentrated load over a bearing of 3.5 in. The web local yielding strength is (5 × 1.0 + 3.5) × 50 × 0.305 = 129.6 kips. The web local crippling strength is 0.75 × 150.8 = 113.1 kips, so crippling governs. A load of 90 kips is 0.80 of the strength, and the web is adequate.

Why it matters

The calculator helps structural engineers, steel detailers, fabricators and students to check a beam web under a support reaction, a column load or a hanger, before they add stiffeners, and to see how the length of bearing changes the strength.

Good to know

Take k from the table of the section, in the design value, and the real length of bearing of the load, not the width of the plate. For a reaction at the end, check the case where N/d is over 0.2 with the second equation. If the ratio is over 1, test a longer bearing before you add stiffeners, since a few inches may be enough, and keep the factored load as the reaction of the load combination.

The web shear buckling capacity calculator checks the web in shear, the beam bearing length calculator gives the bearing on a support, the steel column capacity calculator gives the axial capacity of a column and the base plate size calculator sizes the plate under a column.

Frequently asked questions

What are web local yielding and web local crippling?

A concentrated load or a support reaction on the flange of a beam creates a high compression in the web just under the load. Web local yielding is the yielding of the web over a length of bearing spread at 2.5 to 1 from the flange. Web local crippling is the buckling of the web under the load. Chapter J10 of the AISC specification gives the strength for each state, and the smaller one governs.

What are the equations?

For web local yielding, the nominal strength is (5k + N) Fy tw for a load away from the end and (2.5k + N) Fy tw at the end, with a factor phi of 1.00. For web local crippling away from the end, it is 0.80 tw² [1 + 3 (N/d)(tw/tf)^1.5] √(E Fy tf/tw), with a factor phi of 0.75. At the end the constant is 0.40, and the term changes when N/d is above 0.2.

What can I do if the web is not enough?

Lengthen the bearing, use a plate or a stiffer seat under the load, choose a beam with a thicker web, or add bearing stiffeners welded to the web and fitted to the flange, which then carry the load. Stiffeners of the full depth are used for large reactions, and a half-depth stiffener may be enough when only the yielding of the web governs.

What does the calculator leave out?

The calculator checks the two limit states for a rolled beam with the loads on the compression flange and gives no result for the sidesway web buckling, the flange local bending, the shear of the web or the bearing of the supports. It assumes that the load is not closer to the end than d/2 for the interior case. Check the other limit states of the specification, and follow your national code.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.