Skip to content
Omnikalc

Web shear buckling calculator: design shear strength of a plate girder web

Enter the depth and thickness of the web, the steel strength, the stiffener spacing and the factored shear to get the slenderness, kv, Cv1, the design shear strength and the demand to capacity ratio.

Updated on
Your inputs
in

Value out of range

in

Value out of range

ksi

Value out of range

in

Value out of range

kips

Value out of range

Results

Design shear strength (φVn)

207.8 kips

Web slenderness h/tw
160.0
Shear buckling coefficient kv
10.00
Web shear coefficient Cv1
0.342
Demand to capacity ratio
0.87
The web resists the factored shear without tension field action

The web shear buckling calculator gives the web slenderness, the buckling coefficient kv, the coefficient Cv1, the design shear strength and the demand to capacity ratio of a stiffened or unstiffened plate girder web by AISC 360 section G2, without tension field action.

How the calculation works

  • Enter the clear depth and the thickness of the web, and the yield strength of the steel.
  • Enter the spacing of the transverse stiffeners, or 0 for an unstiffened web, and the factored shear force.
  • The calculator finds the web slenderness, the buckling coefficient kv, the coefficient Cv1, the design shear strength of the web and the demand to capacity ratio, without tension field action.

Example

A plate girder web is 60 in deep and 0.375 in thick, in steel of 50 ksi, with stiffeners every 60 in. Then h/tw = 160, a/h = 1 and kv = 5 + 5 / 1² = 10. The limits are 1.10 √(10 × 29,000 / 50) = 83.8 and 1.37 √(10 × 29,000 / 50) = 104.3, so the web is slender and Cv1 = 1.51 × 10 × 29,000 / (160² × 50) = 0.342. The strength is φVn = 0.9 × 0.6 × 50 × 60 × 0.375 × 0.342 = 207.8 kips, and a shear of 180 kips gives a ratio of 0.87.

Why it matters

The calculator helps steel and bridge designers, fabricators, plan checkers and students to check the shear strength of a deep web in a first design, and to see how much the transverse stiffeners and the thickness of the web improve the strength.

Good to know

Check the shear and the bending moment together where they are high, add bearing stiffeners at the supports and under the heavy loads, and use the tension field action of section G3 if the web is thin and the stiffeners are close. Control the weld between the web and the flanges.

The steel beam LTB calculator gives the bending strength, the beam deflection calculator checks the deflection, the beam bearing length calculator checks the web at the support and the load combinations calculator gives the factored loads.

Frequently asked questions

What is the shear buckling of a web?

The web of a deep and thin steel girder carries the shear, and under a high shear it can buckle in a diagonal pattern before the steel yields. The strength of the web in shear is then lower than the yield value 0.6 Fy Aw. The reduction depends on the slenderness h/tw of the web, on the spacing of the transverse stiffeners and on the yield strength.

How is the web strength calculated?

AISC 360 section G2.1 gives the nominal shear strength Vn = 0.6 Fy Aw Cv1, with Aw = h tw. The coefficient Cv1 is 1.0 for a compact web, h/tw ≤ 1.10 √(kv E/Fy). It is 1.10 √(kv E/Fy) / (h/tw) for a web of intermediate slenderness, and 1.51 kv E / ((h/tw)² Fy) for a slender web. The buckling coefficient is kv = 5 for an unstiffened web, and kv = 5 + 5/(a/h)² for a stiffened one, where a is the stiffener spacing.

Why add transverse stiffeners?

Stiffeners reduce the width of the panel a/h and increase the buckling coefficient kv, so they increase the strength of the web in shear. The effect is large for a slender web. Beyond the buckling, a stiffened web can also carry more load by tension field action, with the stiffeners as vertical struts, which the calculator does not include and which is given in section G3 of the specification.

What are the limits of the calculator?

The calculator gives the shear strength without tension field action. It uses φ = 0.90 for all webs, while rolled I-shapes with a compact web can use φ = 1.00, and it does not include the interaction between the shear and the bending, the bearing stiffeners, the web crippling, the fatigue or the shear in the flanges. A plate girder must be designed by a qualified engineer.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.