Thermal penetration depth calculator: how far heat travels into a material

Choose a material and a time, and get the depth where 50%, 16% and 1% of a surface temperature change is felt, and the time for the change to cross a wall of a given thickness.

Updated on
Your inputs
h

Value out of range

in

Value out of range

Results

Depth reached by half of the surface change (50%)

9.2 in

Depth reached by 16% of the surface change
19.4 in
Depth reached by 1% of the surface change
35.3 in
Penetration ratio: 1% depth over thickness
4.41
The change has crossed the wall: use a finite-thickness model
Time for 1% of the change to reach the far face
1.23 h

The thermal penetration depth tells how far heat has moved into a wall, a slab or the ground after a given time. The thermal penetration depth calculator uses the semi-infinite solid solution to give the depth of the 50%, 16% and 1% levels and the time to cross a wall.

How the calculation works

  • Choose the material to set its thermal diffusivity α, then enter the time since the surface temperature changed and the thickness of the wall or slab.
  • The calculator uses the semi-infinite solid solution θ = erfc[x / (2√(αt))], the temperature response of a body whose surface is suddenly held at a new temperature.
  • It gives the depth where 50%, 16% and 1% of the surface change is felt. These depths are 0.954, 2.0 and 3.64 times √(αt).
  • It compares the 1% depth with the thickness and gives the time needed for the change to reach the far face.

Example

A concrete wall (α = 0.7 mm²/s) is 8 in thick. Its surface is heated for 24 h. The length √(αt) is √(0.7 × 3,600 × 24) = 245.9 mm. Half of the surface change is felt down to 0.9539 × 245.9 mm = 9.2 in, 16% down to 19.4 in and 1% down to 35.3 in. The ratio of the 1% depth to the 8 in thickness is 4.41, so the wall is thermally thin at 24 h: the far face is reached after only 1.23 h.

Why it matters

The calculator helps building engineers, geotechnical engineers, pavement and concrete specialists, mechanical designers and students to know how deep a temperature change goes, how long a wall takes to respond, and how thick a mass wall must be to damp a daily swing. It is a quick check before a numerical simulation.

Good to know

Use the correct diffusivity of the real material, including moisture, since wet soil and concrete change it. Remember that the depth grows only with √t: doubling the depth takes four times longer. Compare the 1% depth with the thickness, and switch to a finite slab model when the ratio is above 1.

The Fourier number calculator tests the transient response of a slab, the Biot number calculator checks the surface effect, the frost penetration depth calculator covers freezing in soil and the heat loss calculator gives the steady heat flow.

Frequently asked questions

What is the thermal penetration depth?

When the surface of a solid is suddenly heated or cooled, the change moves inside as heat diffuses. The penetration depth measures how far a given share of the surface change has traveled after a given time. It grows with the square root of time and of the thermal diffusivity: a depth four times larger needs sixteen times more time. It is the key scale for transient heat conduction in walls, soil, pavements and metal parts.

What is thermal diffusivity?

The thermal diffusivity α is the conductivity divided by the product of density and specific heat. It tells how fast a temperature change spreads. Copper has a diffusivity of about 111 mm²/s and conducts a change very quickly. Concrete (0.7 mm²/s) and wood (0.15 mm²/s) are slow, which is why a thick masonry wall damps the daily temperature swing and keeps a house cool in summer.

Where do the factors 0.954, 2 and 3.64 come from?

The semi-infinite solution says that the remaining share of the surface change at depth x is erfc[x / (2√(αt))]. The complementary error function is 0.5 at an argument of 0.477, 0.157 at 1.0 and 0.01 at 1.82. Multiplying these arguments by 2√(αt) gives the factors 0.954, 2.0 and 3.64 times √(αt), so you can choose the share that matters for your case.

When is the semi-infinite model not valid?

The model assumes that the body is infinitely thick and that the surface changes at once to a constant temperature. When the 1% depth is larger than the real thickness, the far face has felt the change and the answer is too deep: use a slab model with the Fourier number. A surface with a slow film of air, a coated wall or a periodic change also needs another model.