The trench dewatering calculator estimates the inflow to a trench and the number of wellpoints needed to keep it dry, from the soil conductivity, the water table, the trench length and the Sichardt radius of influence, with a design pumping rate.
How the calculation works
- Enter the hydraulic conductivity of the soil, the height of the water table and the water level to keep in the trench, both above the base of the aquifer.
- Enter the length of the trench, the wellpoint spacing and the design factor for the flow.
- The calculator finds the radius of influence R = 3000 s √k from Sichardt and the inflow to the trench from Dupuit’s equation, q = k (H² − h²) / R.
- It gives the steady inflow, the design pumping rate, the number of wellpoints and the flow each one takes.
Example
A trench 200 ft long is dug in sand with k = 50 ft/day. The water table is 20 ft above the base of the aquifer and must be kept at 5 ft. The drawdown is 15 ft (4.572 m) and k is 1.764 × 10⁻⁴ m/s, so the radius of influence is 3000 × 4.572 × √(1.764 × 10⁻⁴) = 182.2 m, or 597.7 ft, and the inflow is 50 × (400 − 25) / 597.7 = 31.37 ft³/day per ft. Over 200 ft that is 32.6 gpm, and with a design factor of 1.5 the pumping rate is 48.9 gpm. At a spacing of 5 ft, 200 / 5 + 1 = 41 wellpoints are needed, each taking 1.19 gpm.
Why it matters
The calculator helps contractors, geotechnical and civil engineers, and students to estimate the size of the pumps and the number of wellpoints for a pipeline or foundation trench below the water table, and to compare different spacings. It gives a first estimate before a pumping test and a design by a dewatering specialist.
Good to know
Use a conductivity from a pumping test or a grain-size correlation, and keep a design factor of 1.5 or more for uncertain soils. Add the rainfall, the leaks through the trench walls and the water of the pipes. Keep the water level at least 2 to 3 ft (0.6 to 1 m) under the trench bottom. Check the effect of the drawdown on nearby buildings, which can settle, and obtain the discharge permit.
Related tools
The well drawdown calculator gives the drawdown of a pumped well, the dry well calculator covers infiltration, the earthwork swell and shrink calculator covers excavated volumes and the wet well volume calculator sizes pump sumps.