Skip to content
Omnikalc

Trench dewatering calculator: wellpoint system design with the Sichardt radius of influence

Enter the soil conductivity, the water table, the trench level, the trench length and the wellpoint spacing to get the radius of influence, the inflow, the design pumping rate and the number of wellpoints.

Updated on
Your inputs
ft/day

Value out of range

ft

Value out of range

ft

Value out of range

ft

Value out of range

ft

Value out of range

Results

Design pumping rate

48.9 gpm

Radius of influence (Sichardt)
597.7 ft
Inflow per length of trench (both sides)
31.37 ft³/day per ft
Steady inflow to the trench
32.6 gpm
Number of wellpoints
41
Flow per wellpoint
1.19 gpm
Within the capacity of a normal wellpoint

The trench dewatering calculator estimates the inflow to a trench and the number of wellpoints needed to keep it dry, from the soil conductivity, the water table, the trench length and the Sichardt radius of influence, with a design pumping rate.

How the calculation works

  • Enter the hydraulic conductivity of the soil, the height of the water table and the water level to keep in the trench, both above the base of the aquifer.
  • Enter the length of the trench, the wellpoint spacing and the design factor for the flow.
  • The calculator finds the radius of influence R = 3000 s √k from Sichardt and the inflow to the trench from Dupuit’s equation, q = k (H² − h²) / R.
  • It gives the steady inflow, the design pumping rate, the number of wellpoints and the flow each one takes.

Example

A trench 200 ft long is dug in sand with k = 50 ft/day. The water table is 20 ft above the base of the aquifer and must be kept at 5 ft. The drawdown is 15 ft (4.572 m) and k is 1.764 × 10⁻⁴ m/s, so the radius of influence is 3000 × 4.572 × √(1.764 × 10⁻⁴) = 182.2 m, or 597.7 ft, and the inflow is 50 × (400 − 25) / 597.7 = 31.37 ft³/day per ft. Over 200 ft that is 32.6 gpm, and with a design factor of 1.5 the pumping rate is 48.9 gpm. At a spacing of 5 ft, 200 / 5 + 1 = 41 wellpoints are needed, each taking 1.19 gpm.

Why it matters

The calculator helps contractors, geotechnical and civil engineers, and students to estimate the size of the pumps and the number of wellpoints for a pipeline or foundation trench below the water table, and to compare different spacings. It gives a first estimate before a pumping test and a design by a dewatering specialist.

Good to know

Use a conductivity from a pumping test or a grain-size correlation, and keep a design factor of 1.5 or more for uncertain soils. Add the rainfall, the leaks through the trench walls and the water of the pipes. Keep the water level at least 2 to 3 ft (0.6 to 1 m) under the trench bottom. Check the effect of the drawdown on nearby buildings, which can settle, and obtain the discharge permit.

The well drawdown calculator gives the drawdown of a pumped well, the dry well calculator covers infiltration, the earthwork swell and shrink calculator covers excavated volumes and the wet well volume calculator sizes pump sumps.

Frequently asked questions

What is a wellpoint system?

A wellpoint system lowers the water table around an excavation with a line of small-diameter wells, called wellpoints, driven or jetted into the ground at a short spacing, usually 2.5 to 10 ft (0.75 to 3 m). They are connected to a header pipe and a vacuum pump. The system works best in sands and silty sands, and the suction lift limits the drawdown of a single stage to about 15 to 20 ft (5 to 6 m).

What is the radius of influence?

The radius of influence is the distance from the dewatered area at which the water table is no longer lowered. Sichardt’s empirical formula gives R = 3000 s √k, with the drawdown s and R in meters and the conductivity k in m/s. It is an approximation, and a pumping test gives better results. The inflow depends on R only through a logarithm or a linear term, so the result is not very sensitive to errors in R.

How is the flow found?

For a long trench, the flow to a line of wells on both sides can be taken as q = k (H² − h²) / R per unit length, where H is the initial water head, h the head kept in the trench and R the distance to the zone not affected. This is the steady-state equation for an unconfined aquifer resting on an impervious base. For a partly penetrating system or a confined layer, more detailed equations are used.

What are the limits of the method?

The calculation assumes a homogeneous aquifer on an impervious base, and a steady flow. Layered soils, nearby rivers or recharge, and the storage of the soil during the first days of pumping change the flow. The conductivity is the main uncertainty, and a variation by a factor of 2 or 10 is possible. A design factor and pumping tests on site are essential, and a specialist contractor should design the system.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.