Skip to content
Omnikalc

Philip infiltration equation calculator

Enter the sorptivity and the steady-rate parameter of a soil, a time, a rainfall intensity and a storm duration to get the cumulative infiltration, the infiltration rate, the ponding time and the runoff.

Updated on
Your inputs
in/√h

Value out of range

in/h

Value out of range

h

Value out of range

in/h

Value out of range

h

Value out of range

Results

Cumulative infiltration at the given time

1.73 in

Ponding time under the rain (shown as 999 if it never ponds)

19.6 min

Approximate runoff during the storm

0.82 in

Infiltration rate at the given time
0.58 in/h
Mean infiltration rate since the start
0.87 in/h
Water infiltrated during the storm
2.18 in
Share of the rain that runs off
27 %

The Philip infiltration equation calculator gives the cumulative infiltration and the infiltration rate of a soil from its sorptivity and its steady-rate parameter, then finds the ponding time under a steady rain and the approximate runoff during a storm.

How the calculation works

  • Enter the sorptivity S and the parameter A of the soil, and the time at which you want the infiltration.
  • Enter the rainfall intensity and the duration of the storm.
  • Read the cumulative infiltration, the rate, the ponding time and the runoff.

Example

With a sorptivity of 0.8 in/√h and A of 0.3 in/h, the soil has absorbed 1.73 in after 2 h, at a rate of 0.58 in/h that averages 0.87 in/h since the start. Under rain of 1 in/h, the surface starts to pond after 19.6 min. In a storm of 3 h, the soil takes up 2.18 in and the runoff is about 0.82 in, or 27 % of the rain.

Why it matters

The calculator helps students of soil physics and hydrology, irrigation designers and land managers who want to see how quickly a soil takes water, whether a given rain or sprinkler intensity will pond, and how much of a storm could run off a bare field.

Good to know

The two parameters come from field or laboratory measurements, for example from a tension infiltrometer. For a rough check, A is often taken between one third and two thirds of the saturated hydraulic conductivity. The sorptivity depends strongly on the initial moisture, so a wet soil gives a much lower S and more runoff. The equation is valid for homogeneous soil and not for very long times, where the infiltration rate settles at the saturated conductivity. A crust, a slope, or a compacted layer can change the result a lot. Use the values as an estimate, not as a design guarantee.

The soil permeability test calculator measures hydraulic conductivity, the infiltration trench sizing calculator designs a stormwater facility, the swale calculator sizes a vegetated channel and the available water capacity calculator describes what the soil holds.

Frequently asked questions

What is the Philip equation?

In 1957, John Philip published a series solution of the equation of water flow in an unsaturated soil. Its two-term form gives the cumulative infiltration F = S√t + A·t, where S is the sorptivity of the soil and A a parameter close to the saturated conductivity. The infiltration rate is the derivative, i = S / (2√t) + A, which starts high and falls toward A.

What is sorptivity?

Sorptivity measures the ability of a soil to absorb water by capillarity, independent of gravity. It is high for a dry soil, a fine texture with a good structure, and it is low for a soil that is already wet. It is expressed in length per square root of time. It is measured with a small tension disc infiltrometer.

What is the ponding time?

When it rains harder than the soil can absorb, the water starts to collect on the surface. Under a constant rain intensity r, larger than A, the ponding time is tp = S² / [4 (r − A)²]. Before this time all the rain infiltrates, and after it the surface is saturated and the extra rain runs off or collects in puddles.

How accurate is the runoff estimate?

It is approximate. The calculation uses the time compression idea, which shifts the infiltration curve at ponding, but it assumes a uniform soil, a flat surface with no depression storage and a constant rain intensity. The two-term equation is also reliable only for short to moderate times. For design work, use measured data and a hydrologic model.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.