The channel lining tractive force calculator gives the shear stress on the bed and the banks of an open channel and the riprap size D50 needed to resist it, from the depth of flow, the slope, the side slope and the Shields parameter.
How the calculation works
- Enter the depth of flow and the slope of the channel, for the design discharge.
- Choose the side slope of the banks. The riprap on a steep bank is less stable, so a side slope factor K is applied (angle of repose of 40°).
- Enter the Shields parameter (about 0.047 for a turbulent flow) and a safety factor.
- The calculator finds the shear stress on the bed (γ d S) and on the side slope (0.76 of the bed), and the median size D50 of the riprap needed for each.
Example
A channel has a depth of flow of 3 ft and a slope of 0.01. The maximum shear on the bed is 62.4 × 3 × 0.01 = 1.87 lb/ft² and on the side slope it is 0.76 × 1.87 = 1.42 lb/ft². With 2H : 1V banks, K = 0.718. With Shields = 0.047 and a safety factor of 1.5, the D50 needed on the bed is 12 × 1.5 × 1.87 / (0.047 × 1.65 × 62.4) = 7.0 in, and 7.4 in on the side slope.
Why it matters
The calculator helps civil and environmental engineers, drainage designers, contractors and students to choose the size of the stones that protect a ditch or a channel from erosion, to compare the bed with the banks and to see the effect of the slope and of the depth. It is a first step before the detailed design of the lining.
Good to know
Use the depth of the design flood and the slope of the energy grade, not only that of the bed. Increase the shear in the bends and downstream of structures. Provide a filter layer, a thickness of at least twice the D50 and a toe protection, and check the stability of the lining at the transitions.
Related tools
The Manning equation calculator gives the depth and the velocity of the flow, the riprap calculator sizes the stone of a slope, the critical depth calculator checks the flow regime and the bridge pier scour calculator covers the scour at a pier.